Characteristics
Acoustic Absorption
αw=1 classe=A NRC=0.95
αp, Practical sound absorption coefficient
Frequency Hz
Fire Reaction
| Standard | Class |
|---|---|
| EN 13501-1 | A2-s1,d0 |
Fire Resistance
| Standard | Classification | Size | Load-bearing structures | Additional insulation |
|---|---|---|---|---|
| EN 13501-2 | REI 30 | 600x600x40 | Concrete, Steel | - |
| EN 13501-2 | REI 30 | 600x600x40 | Concrete, Steel, Timber | 160 mm Eurolène® 603 |
| NBN 713-020 | SF 30 | 600 to 1200 x 600x40 | Concrete, Steel | - |
| NBN 713-020 | SF 30 | 600 to 1200 x 600x40 | Concrete, Steel, Timber | 160 mm Eurolène® 603 |
See respective classification reports for detailed information on installation and suspension system requirements.
Impact Resistance
| Product | Main Runner | Euroclips | Wall Spring |
|---|---|---|---|
| 1200x600 | cc 1200 | 4.2 / m² | 1 / perimeter tile |
| 1500x1000 | cc 1500 | 2 / m² | 1 / perimeter tile |
Tested and classified 2A according EN 13964 - Annex D when installed with Quick-Lock® T24 grid system.
Humidity Resistance
100% flat irrespective of the Relative Humidity.
Implementation and maintenance
Installation
| • You are advised to ensure that air can circulate between the rooms and the plenum to balance the temperature and pressures on each side of the ceiling. |
| • Tiles can be cut with a craft knife without generating any noise or dust. |
| • The direction in which the panels should be installed is indicated on the back of the panels. |
| • Contact us if any mineral wool is to be laid in the plenum. |
Cleanability
The ceiling surface does not retain dust, which makes the panels easier to clean. The ceiling can be cleaned using a light brush or a vacuum cleaner. This type of cleaning will help extend the service life of the ceilings.
Certifications
Material Health
| EUCEB | Eurocoustic panels are manufactured using mineral wool certified by the European Certification Board for mineral wool products (EUCEB), which independently confirms that mineral wool is produced in conformity with the Note Q of European Regulation (EC) No 1272/2008 and therefore classification as a carcinogen does not apply. |
| REACH | Eurocoustic products comply with the REACH regulation of the European Chemicals Agency and therefore do not contain any Substances of Very High Concern (SVHC) with potential negative impacts on human health or the environment above 100ppm. |
Circularity
| Minimum recycled content | 26% |
| Recyclability | Fully recyclable |
Ce Markings
Eurocoustic ceilings are CE marked according to the European harmonized standard EN13964:2014. CE marked construction products are covered by a Declaration of Performance (DOP) which enables customers and users to easily compare performance of products available on the European market.
Indoor Air Quality
| Certificate / Label | |
|---|---|
| French VOC | A+ |
Carbon Footprint
| kg CO₂ equiv/m² | |
|---|---|
| Acoustichoc A 40 | 6.56 |
Life cycle stages A1 to C4 of the EPD, in compliance with ISO 14025 / EN 15804.
Colors
colors
Calcaire D2
|
White
|
Chrome M2
|