Eurocoustic Minerval A22 environmental image
Office
Education

Minerval® A 22

Minerval® A22 is an economical and efficient ceiling solution, ideal for all types of rooms.

• Acoustic absorption: αw = 1.00
• Reaction to fire : A1
• Eurofins Indoor Air Comfort® Gold certified
• Cradle to Cradle® certified Bronze v4.0

See the documentation

Characteristics

Acoustic Absorption

αw=1 classe=A NRC=0.95

αp, Practical sound absorption coefficient

Eurocoustic Minerval® A 22_graph_1

Frequency Hz

Visual Appearance
Property White
Light Reflectance (LRV%) 78%
Whiteness (L*) 91%
Gloss (85°) 1.1
Fire Reaction
Standard Classification
EN 13501-1 Euroclass A1
Fire Resistance
Standard Classification Size Load-bearing structures Additional insulation
EN 13501-2 REI 30 600x600 Concrete, Steel -
EN 13501-2 REI 30 600x600 Concrete, Steel, Timber 160 mm Eurolène® 603
NBN 713-020 SF 30 600 to 1200 x 600 Concrete, Steel -
NBN 713-020 SF 30 600 to 1200 x 600 Concrete, Steel, Timber 160 mm Eurolène® 603
NBN 713-020 SF 30 1200 to 2400 x 600 Concrete, Steel -
See respective classification reports for detailed information on installation and suspension system requirements.

Humidity Resistance

100% flat irrespective of the Relative Humidity.

Implementation and maintenance

Installation
• You are advised to ensure that air can circulate between the rooms and the plenum to balance the temperature and pressures on each side of the ceiling.
• Tiles can be cut with a craft knife without generating any noise or dust.
• The direction in which the panels should be installed is indicated on the back of the panels.
• Contact us if any mineral wool is to be laid in the plenum.

Cleanability

The ceiling surface does not retain dust, which makes the panels easier to clean. The ceiling can be cleaned using a light brush or a vacuum cleaner. This type of cleaning will help extend the service life of the ceilings.

Certifications

Material Health
C2C Certified Material Health Certificate™ This product has received a C2C Certified Material Health Certificate™ at the Bronze level (standard version 4.0). The C2C Certified Material Health Certificate™ is a verification of the health and safety of a product’s composition using the Material Health requirements of the Cradle-to-Cradle Certified Product Standard.
EUCEB Eurocoustic panels are manufactured using mineral wool certified by the European Certification Board for mineral wool products (EUCEB), which independently confirms that mineral wool is produced in conformity with the Note Q of European Regulation (EC) No 1272/2008 and therefore classification as a carcinogen does not apply.
REACH Eurocoustic products comply with the REACH regulation of the European Chemicals Agency and therefore do not contain any Substances of Very High Concern (SVHC) with potential negative impacts on human health or the environment above 100ppm.
Circularity
Minimum recycled content 24%
Recyclability Fully recyclable

Ce Markings

Eurocoustic ceilings are CE marked according to the European harmonized standard EN13964:2014. CE marked construction products are covered by a Declaration of Performance (DOP) which enables customers and users to easily compare performance of products available on the European market.

Cradle to cradle

This product is Cradle to Cradle Certified® at Bronze level (version 4.0).
Indoor Air Quality
Certificate / Label
French VOC A+
Eurofins Indoor Air Comfort® Gold
Carbon Footprint
kg CO₂ equiv/m²
Minerval A 22 3.58
Life cycle stages A1 to C4 of the EPD, in compliance with ISO 14025 / EN 15804.

Colors

color

Blanc
White
|
NCS
Nearest NCS: S 1000-N Light reflectance: 78 %

Documents

Cradle to Cradle
Minerval® A 15 test III
Tonga® Therm A
Minerval® E 15
Tonga® E 20
Minerval® A 12
Tonga® A 22
Minerval® A 22
Tonga® A 40
Tonga® Ultra Clean A 20
PDF | 1 page | 155.05 KB
SaintEurocBronzCERT62732024-01-1115240.pdf
Cradle to Cradle
Minerval® A 15 test III
Tonga® Therm A
Minerval® E 15
Tonga® E 20
Minerval® A 12
Tonga® A 22
Minerval® A 22
Tonga® A 40
Tonga® Ultra Clean A 20
PDF | 1 page | 135.44 KB
SaintEurocBronzMHC62732025-05-0614521.pdf
Emissions
Minerval® A 15 test III
Minerval® A 12
Minerval® A 22
PDF | 2 pages | 1.24 MB
38IACG-400-17-38-2024IndoorAirComfortGoldCertificateENMINERVAL.pdf
Environmental Product Declaration - EPD
Minerval® A 15 test III
Minerval® A 12
Minerval® A 22
PDF | 14 pages | 2.55 MB
EPDMinervalA.pdf
Declaration of Performance - DoP
Minerval® A 12
Minerval® A 22
Minerval® A 15 test III
PDF | 46 pages | 877.37 KB
G001DOPMinervalA2025-12-04.pdf
Test report Fire Resistance
Minerval® A 22
PDF | 16 pages | 752.12 KB
ResistenzaalfuocoMinervalA22mm-it-21852-1.pdf
Test report Sound absorption
Minerval® A 22
PDF | 3 pages | 181.72 KB
AcousticAbsorption-MINERVALA22-EN-it-19097-1.pdf
Test report Fire
Tonga® A 22
Minerval® A 22
Acoustichoc® A 22
PDF | 10 pages | 323.33 KB
2021-A-004BSfFR.pdf
Test report Fire
Tonga® A 22
Minerval® A 22
Acoustichoc® A 22
PDF | 10 pages | 307.83 KB
2021-A-004BSfNL.pdf
Product page
Minerval® A 22
PDF | 4 pages | 701.06 KB
ProductbrochureMinervalA22CM.pdf